I’m in the process of wiring a home before moving in and getting excited about running 10g from my server to the computer. Then I see 25g gear isn’t that much more expensive so I might was well run at least one fiber line. But what kind of three node ceph monster will it take to make use of any of this bandwidth (plus run all my Proxmox VMs and LXCs in HA) and how much heat will I have to deal with. What’s your experience with high speed homelab NAS builds and the electric bill shock that comes later? Epyc 7002 series looks perfect but seems to idle high.

  • scarecrow365@reddthat.com
    link
    fedilink
    English
    arrow-up
    18
    ·
    6 months ago

    I’ve got a 3 node Proxmox/ceph cluster with 10G, plus a separate Nas. They are all rack mount with dual PSU. Add in the necessary switching, and my average load is about 800w. Throw my desktop (also on 10G) into the mix and it runs 1.1kw.

    That’s roughly $50-60 extra in electricity costs for me monthly.

    • Cobrachicken@lemmy.world
      link
      fedilink
      English
      arrow-up
      16
      ·
      6 months ago

      Would be around 300€ in Germany, on a cheap contract. Limiting myself to one combined NAS/application server atm, with the others turned on only if I want to try sth out.

        • tmjaea@lemmy.world
          link
          fedilink
          English
          arrow-up
          3
          ·
          6 months ago

          Average load 800W is 0.8kW24h30d=576kWh/M

          Which is over 172€ on a 30ct/kWh contract.

          • jqubed@lemmy.world
            link
            fedilink
            English
            arrow-up
            3
            ·
            6 months ago

            Wow! I’m paying 10.5¢/kWh for electricity at home here in the US; it’s a little below the national average but not dramatically.

            • tmjaea@lemmy.world
              link
              fedilink
              English
              arrow-up
              2
              ·
              6 months ago

              Yeah, we pay a lot. We also got one of the lowest downtimes regarding electricity, on average approximately 10minutes per year…so that’s kind of a (small) advantage you get for the premium price

    • kylian0087@lemmy.dbzer0.com
      link
      fedilink
      English
      arrow-up
      1
      ·
      6 months ago

      I ise about the same. But that is more due to the hardware I got being a bit older. 2 dell R710s 1 R510 and a custom build server. Everything is still 1g. In my case electricity is not a big deal due to solar. We produce much more then we can use our self.

    • johnnixon@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      6 months ago

      I’m afraid of dumping 500+ watts into a (air conditioned) closet. How are you able to saturate the 10g? I had some idea that ceph speed is that of the slowest drive, so even SATA SSDs won’t fill the bucket. I imagine this is due to file redundancy not parity/striping spreading the data. I’d like to stick to lower power consumer gear but ceph looks CPU, RAM, and bandwidth (storage and network) hungry plus low latency.

      I ran proxmox/ceph over 1GB on e-waste mini PCs and it was… unreliable. Now my NAS is my HA storage but I’m not thrilled to beat up QLC NAND for hobby VMs.

      • scarecrow365@reddthat.com
        link
        fedilink
        English
        arrow-up
        1
        ·
        6 months ago

        My 10G is far from saturated, but I do try and keep things using RAM where possible. I figure that with 100gb of DDR4 in my main server, that should be able to provide enough speed for a 10G link.

        I’ve got ceph running on Intel Enterprise SSDs, so they are pretty quick.

        I also tried running ceph on 1G. I found it unreliable as well.

  • Rizilia@lemmy.zip
    link
    fedilink
    English
    arrow-up
    15
    ·
    edit-2
    6 months ago

    Around 100 Watts for

    • NAS with 4x3.5" HDD,
    • Minisforum HM90 for Proxmox with 2x2.5" HDDs,
    • 16 Port TP Link PoE Switch,
    • TP Link router
    • 2x Raspberry Pi 4b

    But everything with gigabit speed. Doesnt need more at home

    • johnnixon@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      6 months ago

      I looked at Epyc because I wanted to bandwidth to run u.2 drives at full speed and it wasn’t until Epyc or Threadripper that you could get much more than 40 lanes in a single socket. I’ve got to find another way to saturate 10g and give up on 25g. My home automation is run on a Home Assistant Yellow and works perfectly, for what it does.

      • just_another_person@lemmy.world
        link
        fedilink
        English
        arrow-up
        6
        ·
        edit-2
        6 months ago

        Some unsolicited advice then: don’t go LOOKING for reasons to use the absolute max of what your hardware is capable of just because you can. You just end up spending more money 🤑

        For real though, just get an N100 or something that does what you need. You don’t need to waste money and power on an Epyc if it just sits idle 99% of the time.

        • johnnixon@lemmy.worldOP
          link
          fedilink
          English
          arrow-up
          1
          ·
          6 months ago

          What I need is a 10g storage for my Adobe suite that I can access from my MacBook. I need redundant, fault tolerant storage for my precious data. I need my self hosted services to be high availability. What’s the minimum spec to reach that? I started on the u.2 path when I saw enterprise u.2 drives at similar cost per GB as SATA SSDs but faster and crazy endurance. And when my kid wants to run a Minecraft server with mods for him and his friends, I better have some spare CPU cycles and RAM to keep up.

          • MangoPenguin@lemmy.blahaj.zone
            link
            fedilink
            English
            arrow-up
            3
            ·
            edit-2
            6 months ago

            You could technically do that from like 2x ~$150 used business desktop PCs off ebay, 10th gen Intel CPU models or around there with Core i3/i5 CPUs.

            Throw some M.2 SSDs in each one in a mirror array for storage, add a bit of additional RAM if needed and a 10G NIC. Would probably use about 30-40W total for both of them.

            Minecraft servers are easy to run, they don’t need much especially on a fairly modern CPU with high single thread performance, and only use maybe 6GB of RAM for a modded one.

            You’re not asking for a whole lot out of the hardware, so you could do it cheap if you wanted to.

          • just_another_person@lemmy.world
            link
            fedilink
            English
            arrow-up
            2
            arrow-down
            1
            ·
            edit-2
            6 months ago

            Get a Drobo if you’re that worried about that kind of access then. Make it simple.

            Otherwise anything with two NICs is the same thing.

    • wreckedcarzz@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      ·
      edit-2
      6 months ago

      I just moved my home assistant docker container to a new-to-me Xeon system. It also runs a couple basically idle tasks/containers, so I threw BOINC at it to put it to good use. All wrapped up with Debian 12 on proxmox…

      (I needed USB support for zigbee in ha, and synology yanked driver support from dsm with the latest major version, so ‘let’s just use the new machine’…)

  • ExcessShiv@lemmy.dbzer0.com
    link
    fedilink
    English
    arrow-up
    9
    ·
    6 months ago

    I’m running my smart home entirely from a single NUC running proxmox with VMs and LXCs for my services. It’s pulling ~7W on average

  • Pete90@feddit.de
    link
    fedilink
    English
    arrow-up
    9
    ·
    edit-2
    6 months ago

    You most likely won’t utilize these speeds in a home lab, but I understand why you want them. I do too. I settled for 2.5GBit because that was a sweet spot in terms of speed, cost and power draw. In total, I idle at about 60W for following systems:

    • Lenovo M90q (i7 10700, 32GB, 3 x 1 TB SSD) running Proxmox, 15W idle
    • Custom NAS (Ryzen 2400G, 16GB, 4x12TB HDD)v running Truenas (30W idle)
    • Firewall (N5105, 8GB) running OPNsense (8W idle)
    • FritzBox 6660 Cable, which functions as a glorified access point, 10W idle
    • tburkhol@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      ·
      6 months ago

      With 25 GbE, even 10, I’d be tempted to PXE boot client systems. Maybe still have a local PCIe SSD for windows game files.

      Dunno how that would actually work with Windows, but it was fun when I did it for beowulf nodes. Setting RPis to netboot is a little involved, but you can create an OSMC image and give all your TVs a consistent ‘smart’ interface. You don’t even need 10GbE to be pretty functional for the Pi, but my experience is that WiFi is not fast enough.

  • Decronym@lemmy.decronym.xyzB
    link
    fedilink
    English
    arrow-up
    8
    ·
    edit-2
    6 months ago

    Acronyms, initialisms, abbreviations, contractions, and other phrases which expand to something larger, that I’ve seen in this thread:

    Fewer Letters More Letters
    AP WiFi Access Point
    DHCP Dynamic Host Configuration Protocol, automates assignment of IPs when connecting to a network
    DNS Domain Name Service/System
    HA Home Assistant automation software
    ~ High Availability
    LXC Linux Containers
    NAS Network-Attached Storage
    NUC Next Unit of Computing brand of Intel small computers
    NVMe Non-Volatile Memory Express interface for mass storage
    PCIe Peripheral Component Interconnect Express
    PSU Power Supply Unit
    PiHole Network-wide ad-blocker (DNS sinkhole)
    PoE Power over Ethernet
    RPi Raspberry Pi brand of SBC
    SATA Serial AT Attachment interface for mass storage
    SBC Single-Board Computer
    SSD Solid State Drive mass storage
    Unifi Ubiquiti WiFi hardware brand
    VPS Virtual Private Server (opposed to shared hosting)

    [Thread #782 for this sub, first seen 4th Jun 2024, 04:35] [FAQ] [Full list] [Contact] [Source code]

  • mlaga97@lemmy.mlaga97.space
    link
    fedilink
    English
    arrow-up
    7
    ·
    6 months ago

    125W (Less than $15/month) or so for

    • Ryzen 9 3900X
    • 64GB RAM
    • 2x4TB NVMe (ZFS Mirror)
    • 5x14TB HDD (ZFS RAID-Z2)
    • 2.5GBe Network Card
    • 5-port 2.5GBe Network Switch
    • 5-port 1GBe POE Network Switch w/ one Reolink Camera attached

    I generally leave powerManagement.cpuFreqGovernor = "powersave" in my Nix config as well, which saves about 40W ($4/mo or so) for my typical load as best as I can tell, and I disable it if I’m doing bulk data processing on a time crunch.

  • Dumbkid@lemmy.dbzer0.com
    link
    fedilink
    English
    arrow-up
    5
    ·
    6 months ago

    5950x in an matx board with 15 x 3.5in drives 1 x sata sad 1 x optane u.2 drive (pulls like 10watts) 1 x Nvidia A2000 1 x Lsi 9305 16i 1 x 2.5gbe intel nic 3 x 140 mm fans at full tilt

    Runs at like 120 watts at idle, like 220 watts with a good amount of work and peaks at like 320 watts if I make it do a lot of work

  • NeoNachtwaechter@lemmy.world
    link
    fedilink
    English
    arrow-up
    5
    ·
    6 months ago

    My real server (Nextcloud/NAS/several more vm’s) uses 28 Watts on average. In addition, there is one Pi 4B running, and I don’t even know it’s wattage.

    I’m planning on replacing the real server with a new one, with lots of cores and approx. 50 Watts then.

  • JustEnoughDucks@feddit.nl
    link
    fedilink
    English
    arrow-up
    5
    ·
    6 months ago

    I have an ITX Ryzen 2700X with an arc A380. 3 HDDs and 1 SSD boot drive.

    Before some kernel improvements for the A380, my idle wattage was 60W. Without the A380 it was around 35W idle. I am hoping that it is around 45W now because of fixing the high idle wattage of the GPU but I have to measure again.

    Performance is great though. Perfect Jellyfin streaming, home automation, document and media management, file sync, recipe management, etc…

    People tend to over-spec their servers, in my opinion. Unless you are dealing with more than a few dozen clients or so on one server (or having a many-user dedicated streaming server), you really don’t need much.

  • cmnybo@discuss.tchncs.de
    link
    fedilink
    English
    arrow-up
    5
    ·
    6 months ago

    The load on my UPS is around 100-140 watts. That includes my server, firewall, switch, starlink and a unifi access point. I would love to get that power consumption down. I only get 4-5 hours of runtime on battery. Also, the room it’s in is small and it gets really hot in the summer time.

  • Nickall01@lemmy.world
    link
    fedilink
    English
    arrow-up
    4
    ·
    6 months ago
    • Fujitsu motherboard
    • Intel pentium G5600
    • 6 HDD (4 x 4 TB 2 x 8 TB) spinned down
    • 2 SSD for proxmox
    • 6 CT and no VM for now

    it runs at 16W mostly idle

  • farcaller@fstab.sh
    link
    fedilink
    English
    arrow-up
    4
    ·
    6 months ago

    I run 3900X with a 40Gbit fiber, packed with HDDs and nvmes. The box fluctuates around 90-110W use.

      • farcaller@fstab.sh
        link
        fedilink
        English
        arrow-up
        1
        ·
        6 months ago

        I did ran out of pcie, yeah :-( the network peaks at about 26gbit/s, which is the most you can squeeze out of pcie 3.0 x4. I could move the nvmes off the pcie 4.0 x16 (I have two m2 slots on the motherboard itself), but I planned to expand the nvme storage to 4x SSDs and I’m out of the pci lanes on the other end of the fiber either way (that box has all x16 going to the gpu)