I can see the wire break in the cable chain :'(

  • Odious@lemmy.world
    link
    fedilink
    English
    arrow-up
    16
    arrow-down
    1
    ·
    5 months ago

    +1. No idea what’s supposed to lead to this conclusion. I’d say that’s a bad PID tune.

    • IMALlama@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      10
      ·
      5 months ago

      The drops especially are way too steep for this to be a PID tune. There’s too much thermal mass to loose that kind of temperature basically instantly.

      Lots of wandering around? PID tune seems like a good starting point, especially if something on the printer changed. Defying the laws of physics? Something else is going on.

    • ikidd@lemmy.world
      link
      fedilink
      English
      arrow-up
      5
      ·
      5 months ago

      If you got used to looking at your graph and saw those dropouts, you start looking for a physical problem.

    • SzethFriendOfNimi@lemmy.world
      link
      fedilink
      English
      arrow-up
      4
      ·
      5 months ago

      That’s worrying then. He can see the wires broken but it still has enough connectivity to keep chugging.

      On the plus side if the thermistor broke enough that it would keep pumping heat into the system then thermal runaway protection should trigger at least.

      • IMALlama@lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        3
        ·
        5 months ago

        This is basically spot on. It’s not full open, but it’s close. This is the first print I’ve noticed it on. It wasn’t a long print, so I figured I would let it go and see what happened. If Klipper loses it for too long it will go into thermal shutdown. Ask me how I know :(

    • asbestos@lemmy.world
      link
      fedilink
      English
      arrow-up
      4
      ·
      5 months ago

      The short timeframe and variations that are way to high even for a mediocrely tuned PID