    Assuming that these have fairly impressive 100 MB/s sustained write speed, then it’s going to take about 93 hours to write the whole contents of the disk - basically four days. That’s a long time to replace a failed drive in a RAID array; you’d need to consider multiple disks of redundancy just in case another one fails while you’re resilvering the first.

    • AmbiguousProps@lemmy.todayOP
      link
      fedilink
      English
      arrow-up
      11
      ·
      3 months ago

      This is one of the reasons I use unRAID with two parity disks. If one fails, I’ll still have access to my data while I rebuild the data on the replacement drive.

      Although, parity checks with these would take forever, of course…

    • DaPorkchop_
      link
      fedilink
      English
      arrow-up
      2
      ·
      3 months ago

      My 16TB ultrastars get upwards of 180MB/s sustained read and write, these will presumably be faster than that as the density is higher.

      • frezik@midwest.social
        link
        fedilink
        English
        arrow-up
        2
        ·
        3 months ago

        I’m guessing that only works if the file is smaller than the RAM cache of the drives. Transfer a file that’s bigger than that, and it will go fast at first, but then fill the cache and the rate starts to drop closer to 100 MB/s.

        My data hoarder drives are a pair of WD ultrastar 18TB SAS drives on RAID1, and that’s how they tend to behave.

        • DaPorkchop_
          link
          fedilink
          English
          arrow-up
          1
          ·
          edit-2
          3 months ago

          This is for very long sustained writes, like 40TiB at a time. I can’t say I’ve ever noticed any slowdown, but I’ll keep a closer eye on it next time I do another huge copy. I’ve also never seen any kind of noticeable slowdown on my 4 8TB SATA WD golds, although they only get to about 150MB/s each.

          EDIT: The effect would be obvious pretty fast at even moderate write speeds, I’ve never seen a drive with more than a GB of cache. My 16TB drives have 256MB, and the 8TB drives only 64MB of cache.

    • C126@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      2
      ·
      3 months ago

      2 parity is standard and should still be adequate. Likelihood of two failures within four days on the same array is small.

      • dan@upvote.au
        link
        fedilink
        English
        arrow-up
        2
        ·
        3 months ago

        It’s more likely if you bought all the drives from the same store (since that increases the likelihood that they’re from the same batch), so you should make sure that you buy them from different stores.

    • SoGrumpy
      link
      fedilink
      English
      arrow-up
      2
      arrow-down
      4
      ·
      3 months ago

      Except these drives are SMR - not something you’d want in a RAID.

      • Telodzrum@lemmy.world
        link
        fedilink
        English
        arrow-up
        4
        arrow-down
        8
        ·
        3 months ago

        Title literally says SMR for one size and CMR for another. Not that I should expect much from a .ml account.