My Internet provider just installed a 2,5/1Gbps Internet connection and I’ve asked the guys to run a couple of their fiber to connect my router (HP Prodesk with OPNsense) to my server. I didn’t know that the fiber is single mode and all the SFP+ sold used now seems to be all for multi mode fiber (www.bargainhardware.co.ukfor example). The cable is about 30m, can I use a 810nm SFP+ or is it definitely better to use a 1310nm?

  • litchralee@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    1
    ·
    edit-2
    7 months ago

    In my first draft of an answer, I thought about mentioning GPON but then forgot. But now that you mention it, can you describe if the fibres they installed are terminated individually, or are paired up?

    GPON uses just a single fibre for an entire neighborhood, whereas connectivity between servers uses two fibres, which are paired together as a single cable. The exception is for “bidirectional” xcvrs, which like GPON use just one fibre, but these are more of a stopgap than something voluntarily chosen.

    Fortunately, two separate fibres can be paired together to operate as if they were part of the same cable; this is exactly why the LC and SC connectors come in a duplex (aka side-by-side) format.

    But if the ISP does GPON, they may have terminated your internal fibre run using SC, which is very common in that industry. But there’s a thing with GPON specifically, where the industry has moved to polishing the fiber connector ends with an angle, known as Angled Physical Contact (APC) and marked with green connectors, versus the older Ultra Physical Contact (UPC) that has no angle. The benefit of APC is to reduce losses in the ISP’s fibre plant, which helps improve services.

    Whereas in data center and networking, I have never seen anything but UPC, and that’s what xcvrs will expect, with tiny exceptions or if they’re GPON xcvrs.

    So I need to correct my previous statement: to be fully functional as designed, the fiber and xcvr must match all of: wavelength, mode, connector, and the connector’s polish.

    The good news is that this should mostly be moot for your 30 meter run, since the extra losses from mismatched polish should still link up.

    As for that xcvr, please note that it’s an LRM, or Long Range Multimode xcvr. Would it probably work at 30 meters? Probably. But an LR xcvr that is single mode 1310 nm would be ideal.

    • peregus@lemmy.worldOP
      link
      fedilink
      arrow-up
      1
      ·
      7 months ago

      Thanks for your precision! To the ONT arrives a single fiber with a SC/APC connector, but this is not a problem since I will be using the ONT provided and use the 2,5Gb copper port to connect it to OPNsense (looking for a 2,5 Gb PCI card). The 2 fiber that I’ve asked them to run (from OPNsense to server) are terminated with the same SC/APC connectors and I was thinking about using this SC female/female adapter and this SC/APC to LC cable that I’ve just realized that are still APC…I’ll have a look if there are SC/APC to LC/UPC cables

      As for that xcvr, please note that it’s an LRM, or Long Range Multimode xcvr. Would it probably work at 30 meters? Probably. But an LR xcvr that is single mode 1310 nm would be ideal.

      Is it a LRM? Damn, I didn’t realized since I’ve filtered for single mode. If the filter doesn’t work, I’ve no idea which is LR. Would you be so gentle to point to a cheap one for single mode finer?

      • litchralee@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        0
        ·
        7 months ago

        I’ve only looked briefly into APC/UPC adapters, although my intention was to do the opposite of your scenario. In my case, I already had LC/UPC terminated duplex fibre through the house, and I want to use it to move my ISP’s ONT closer to my networking closet. That requires me to convert the ISP’s SC/APC to LC/UPC at the current terminus, then convert it back in my wiring closet. I hadn’t gotten past the planning stage for that move, though.

        Although your ISP was kind enough to run this fibre for you, the price of 30 meters LC/UPC terminated fibre isn’t terribly excessive (at least here in USA), so would it be possible to use their fibre as a pull-string to run new fibre instead? That would avoid all the adapters, although you’d have to be handy and careful with the pull forces allowed on a fibre.

        But I digress. On the xcvr choice, I don’t have any recommendations, as I’m on mobile. But one avenue is to look at a reputable switch manufacturer and find their xcvr list. The big manufacturers (Cisco, HPE/Aruba, etc) will have detailed spec sheets, so you can find the branded one that works for you. And then you can cross-reference that to cheaper, generic, compatible xcvrs.

        • peregus@lemmy.worldOP
          link
          fedilink
          arrow-up
          1
          ·
          7 months ago

          Although your ISP was kind enough to run this fibre for you, the price of 30 meters LC/UPC terminated fibre isn’t terribly excessive (at least here in USA), so would it be possible to use their fibre as a pull-string to run new fibre instead? That would avoid all the adapters, although you’d have to be handy and careful with the pull forces allowed on a fibre.

          The problem is the installation of the connectors. They’ve welded the fiber the SC/APC pigtails, I wouldn’t be able to do that.

          The big manufacturers (Cisco, HPE/Aruba, etc) will have detailed spec sheets, so you can find the branded one that works for you. And then you can cross-reference that to cheaper, generic, compatible xcvrs.

          That would be very very generous of you; in the fiber section I’m pretty ignorant and I’m worried to purchase wrong items 🙈

          • litchralee@sh.itjust.works
            link
            fedilink
            English
            arrow-up
            1
            ·
            7 months ago

            I quickly looked up the HPE/Aruba transceiver document, and starting on page 61 is the table of SFP+ transceivers, specifically describing the frequency and mode. At least from their transceivers, J9151A, J9151E, JL749A, and JL783A would work for your single-mode, 1310 nm needs.

            You will have to do additional research to find generic parts which are equivalent to those transceivers. Good luck in your endeavors!